Filed as smart-trust-phw#18; fix offered as smart-trust-phw#19.

Title: Requirement receive-a-vhl names the Issuer as its actor; it should be the Receiver

In input/fsh/requirements/requirements.fsh, the Requirements instance receive-a-vhl (“Receive VHL or VDHC”) reads:

* description = "Is able to receive a VHL authorization mechanism or a VDHC from a Holder"
* actor[+] = Canonical(Issuer)

The capability described, receiving a VHL or VDHC from a Holder, is the Receiver’s (ActorDefinition/Receiver: “Receiver (system) of Verifiable Health Certificate or Verifiable Health Link”). Its counterpart provide-a-vhl-to-a-receiver names the Holder. Proposed fix:

-* actor[+] = Canonical(Issuer)
+* actor[+] = Canonical(Receiver)

The same change is applied in litlfred/smart-trust-phw (https://github.com/litlfred/smart-trust-phw/pull/1) and can be offered as a pull request here.

Found while mapping the user journeys of litlfred/smart-trust-demo (a CHW app, a clinic EHR and a hospital system abroad each receive a VDHC or VHL from the Holder) to the guide’s actors.